In September we inspected a rental property in Wrexham for a local letting agent. It was a landlord’s periodic inspection, and it ended with an Electrical Installation Condition Report (EICR).

What the first inspection found

We carried out the inspection on 7 September 2026. The overall result was unsatisfactory because of three C2 (potentially dangerous) observations:

  • the cooker was not fused down correctly
  • the protective devices were not compatible with, or the right type and rating for, what they protect
  • the protective devices were not adequate for fault protection

The report also listed eight C3 (improvement recommended) items. A C3 on its own does not make a report unsatisfactory. If the codes are new to you, our guide to EICR codes C1, C2, C3 and FI explains them.

Quote, approval and remedial works

We sent the agent a quote for the remedial works on 10 September. The landlord gave the go-ahead the next day. The visit was arranged with the occupant for 25 September, and we carried out the remedial works that day.

The result

After the works we issued an updated report showing the installation as satisfactory. It has no C1, C2 or FI items. The C3 recommendations are still listed for the landlord to consider, and the report recommends the next inspection within five years.

This is the normal path after a failed EICR: read the codes, fix the C1 and C2 items (and any FI), then get written confirmation from the electrician. In Wales, the landlord must give the contract-holder that confirmation within 14 days of receiving it. We cover the steps in what happens after an unsatisfactory EICR, and the five-year point in how long an EICR lasts for a Welsh rental.

Need an EICR or remedial works?

Stewart Rawson Electrical is NICEIC approved and has been working in Wrexham and Chester since 2010. Our EICR page for Wrexham and Chester covers inspections for landlords and letting agents. Call 07789 264398 or 01978 664757.